Find online auctions and classified ads for new and used metricon prism couplers at labx. The metricon model 2010 m prism coupler utilizes advanced optical waveguiding techniques to rapidly and accurately measure both the thickness and the refractive indexbirefringence of dielectric and polymer films. The initial alignment of prism and sample is performed under gravity and the subsequent gap variation is performed by means of a single actuator operating a flexure stage on which the prism is mounted. Optical reflectometry first center for micro and nanoscience. This document is the main source of information regarding the installation and operation of the prism tool. Optimizing the coupling of light via a prism to highq modes of a microsphere resonator using a nearfield probe l. Advantage of prism coupler spaseries propagation loss, refractive index, and thickness measurement of thin film, bulk material. The flexure stage ensures the maintenance of good parallelism between sample and prism as the gap dimension is varied. Broadband, wavelength flattened or single wavelength. Metricon 2010 prism coupler simple measurement of optical refractive index operating wavelengths. Chapter 5 characterization of thin films by prism coupling.
A prismfilm coupler has been discussed recently by tien, ulrich, and martin as a device to couple efficiently a laser beam into thinfilm dielectric light guides. Aar manual of standards and recommended practices coupler and. The metricon prism coupler an applications overview lambda. The metricon is a prism coupler to measure refractive indices and thicknesses.
Component models are no longer implemented as multiple executables running concurrently, but rather as a single executable. Aerotech ps05 control unit sn 4177173011 metricon 2010 prism coupler sn 22287 seiko ppu411 type. Aar manual of standards and recommended practices coupler and yoke details table of contentsalphabetical subject standard page coupler rotary, type e60, operating rod, use with up to 6 12in. Determination of refractive index, thickness, and the optical losses of thin films from prismfilm coupling measurements julien cardin1, and dominique leduc2 1sifcom, cnrs umr 6176, ensicaen, 6 boulevard du marechaljuin, f14050 caen cedex, france. Please note that prism coupling can cause scratching of. The metricon model 2010m prism coupler offers unmatched ease and accuracy in measuring. The power of the light beam reflected from the prism coupler at the given incidence angle is the recorded parameter 173. Measurement of thin film parameters with a prism couple, appl. A midinfrared prism coupler for bulk and thin film optical analysis bruce e. Metricon model 2010m prism coupler bulk material, thick. This coupler also allows an accurate measurement of the spectrum of propagating modes from which the refractive index and the thickness of the film can be determined. A midinfrared prism coupler for bulk and thin film optical.
The prin cipal scheme of this setup is shown in figure 5. The device is used for determination of refractive index of bulk materials, thin films and liquid materials in the refractive index range of 1. Film thicknessindex measurement the model 2010m prism coupler accurately measures thickness 0. Optimizing the coupling of light via a prism to highq modes. Metricon model 2010m prism coupler bulk material, thick film. To the best of our knowledge, the study of the prisms in. The coupler controls the execution and time evolution of the complete system by synchronizing and controlling the flow of data between the various.
Advantages when measuring refractive index for both thin films. Rj45 8p8c inline coupler, femalefemale, straight, shielded, flange panel mount. Optimizing the coupling of light via a prism to highq. I am looking for coupling prisms for light waveguides applications of index 1. Research equipment for analysis of optical properties of materials. Prism coupler for thin film thickness and refractive index, bulk refractive index. Metricon pc2000, with custom raised aluminum base sn 2040. This system has been used for the observation and characterization of surface plasmon polaritons on thin film structures. The construction and operation of a prismvariablegapsample system or variablegap otto coupler for the excitation of surface electromagnetic modes is reported. Determination of refractive index, thickness, and the optical. Please for clear understanding see the fig 3b in attached file. The cesm coupled model is based on a framework which divides the complete climate system into component models that are connected by a coupler component. Find online auctions and classified ads fornew and used metricon prism couplers at labx.
Anheier, and hong amy qiao pacific northwest national laboratory, 902 battelle blvd. The prism faces are polished to 14wave flatness for the rutile prism adt6 and 18wave flatness for the ggg prism adg6. Advantage of prism coupler spaseries propagation loss, refractive index, and thickness measurement of thin film, bulk. We offer right angle prisms, brewster angle prisms, triangular prisms, and penta prisms made from the highest grade nbk7 and fused silica substrates. The prism coupler, known from experiments on integrated optics, can be used to determine the refractive index and the thickness of a lightguiding thin film. The 2010 m offers unique advantages over conventional refractometers and instruments based on ellipsometry or spectrophotometry. Nov 25, 2008 prior art refractometers include a prism coupler described in paper r. The metricon model 2010 m prism coupler utilizes advanced optical waveguiding techniques to rapidly and accurately measure both the thickness and the refractive indexbirefringence of dielectric and polymer films as well as refractive index of bulk materials. The metricon model 2010m prism coupler utilizes advanced optical waveguiding techniques to rapidly and accurately measure both thickness and the.
Thus in the singlefield mode, the beam is split 5050 at the first surface. Osa measurement of thin film parameters with a prism coupler. The metricon model 2010m prism coupler utilizes advanced optical waveguiding techniques to rapidly and accurately measure both the thickness and the refractive indexbirefringence of dielectric and polymer films. It can therefore allow us to measure refractive index at four different wavelengths and. Metricon model 2010 prism coupler, oem2p40cm laser, aerotech ps2230v the model 2010 prism coupler utilizes advanced optical waveguiding techniques to rapidly and accurately measure both the thickness.
Refractive index and thin film thickness measurement metricon. Prism coupling method of light coupling in waveguides is a dominant method adopted by photonic device fabricators. For access to other resources, such as related publications and details of case studies, or to download the tool itself, see the main prism website. Upon completion, the icon next to the property changes according to the result of model checking. Prior art refractometers include a prism coupler described in paper r. The automated device is used to perform such measurements. The fiber coupler and beam stabilization system of the. If you have half prisms or triangular prisms with prism angles 60 please give details of that. Efficient silicononinsulator fiber coupler fabricated using 248nm deep uv lithography 2 lithography machines. Metricon 2010 single wavelength prism coupler thin film analyzer. Osa theory of prismfilm coupler and thinfilm light guides. The coupling prisms were coated with chrome on opposite faces to avoid leakage of scattered light directly from the input to the output prism.
A midinfrared prism coupler for bulk and thin film. The metricon prism coupler 2010 allows wafer measurements of refractive index and thickness of thin films layer stack. For a list of documents and how to order them, visit the sun documentation center on at. A prism film coupler has been discussed recently by tien, ulrich, and martin as a device to couple efficiently a laser beam into thinfilm dielectric light guides. The initial alignment of prism and sample is performed under gravity and the subsequent gap variation is. Sandoghdar2 1h u mb o ld tu niv ersa z b,i fu ph yka gn aop 10 7 2 ph ys icd ep art mn,f d lu v o fbu 5 067 9 1 r e b z. Metricon 2010 prism coupler 633nm 1550nm, ge detector 1998 1280 price. In this simulation the only source of loss is considered to be the mode mismatch at the. Includes 633hene laser, prism code 957, pc, vga monitor, seiko dpu414 thermal printer. Our system is equipped with four different lasers at wavelength.
Includes 633hene laser, prism prism for measuring high refractive index films of 1. We report the results of simulation showing light coupling in waveguides through prism coupling method. Smit abstractthe efficiency and the selectivity of the prismcoupler for exciting single modes in narrow planar optical waveguides is investi. Prismcoupling of light into narrow planar optical waveguides. The influence of the prism coupler on the measured results is also taken into account. Since metricon introduced its first prism coupling system in 1980, more than a thousand systems have been sold to top universities, research labs and companies in more than 40 countries. A prism coupler is a prism designed to couple a substantial fraction of the power contained in a beam of light e. These procedures apply to the metricon model 2010 m prism coupler bulk material, thick film indexbirefringence thickness measurement system. It is necessary to understand the effect various parameters on light coupling in such processes. The microactivity effi catalytic reactor with gas chromatographic system and mass. Metricon 2010 single wavelength prism coupler thin film. Determination of refractive index, thickness, and the. Metricon model 2010 prism coupler, oem2p40cm laser, aerotech ps2230v the model 2010 prism coupler utilizes advanced optical waveguiding techniques to rapidly and. We present here a theory of the prism film coupler.
High resolution measurement for both refractive index and thickness of thinfilm. Aar typeh coupler with onepiece manual trip pin, and kadeestyle shank scale. The metricon model 2010m prism coupler utilizes advanced optical waveguiding techniques to rapidly and accurately measure both the thickness and the. The angles of the prism are tuned such that the exiting beam travels the same path as the dualfield mode. The metricon model 2010m prism coupler bulk material index, thick film. Total draft gear travel s1 siiis145 coupler rotary, type f70, operating rod, use with up to 6 12in. Optics 12 1973 29012908 and a prism coupler found in the metricon 2010 made by metricon corporation, p. Efficient silicononinsulator fiber coupler fabricated. The transmitted part is reflected at the bottom and exits the prism through the ar coated surface. The metricon model 2010m prism coupler utilizes advanced optical. The fundamentals and limitations of this method are discussed, its.